EICR West Bromwich
Electrical installation condition reports (EICR) to the Domestic, Commercial and industrial sectors in and around the West Bromwich and surrounding areas.
EICR Certificate West Bromwich
Industratech carry out Electrical testing services in West Bromwich and the surrounding areas.
Book a trusted engineer to carry out an EICR report, whether at your home or business. Our fully trained staff are on hand to help and assist with any of your electrical testing requirements
Stay up to date and make sure your electrical installation is safe and comply with the latest regulations.
We are insurance recognized NICEIC registered.
Contact us for an EICR quote and then to discuss your specific needs
Domestic EICR in West Bromwich
Your home should have an electrical inspection carried out every 10 years or whether there is a change of ownership. Get your home checked here and book now!
Landlord electrical safety certificate
From the 1st April 2021 it is a legal requirement for landlords to have there electrical installation at there properties to be tested by a fully trained and competent person. The interval between Landlord electrical safety certificate is at least 5 years.

Commercial EICR and Industrial EICR in West Bromwich
Industratech is a leader in carrying out both commercial and industrial testing services across the West Midlands.
Our experience lies in commercial and industrial electrical installations while supported by a skilled and experienced team of engineers.
For both larger and more complex businesses. We understand that each can require a different approach to Electrical Installation Condition Reports (EICR). We work in close partnership with you to plan your EICR schedule around both essential work environments and production activities.
Our flexible approach allows for work to be carried out during out of hours, or to be scheduled at specific days or times that suit your operations. This ensures that your EICR is carried out with minimal disruption and is spread over various periods.
Sectors and types of Buildings
Industratech conducts electrical testing services across a diverse range of buildings and industries. Some examples include:






What are the benefits of using an NICEIC company for your EICR reports in West Bromwich?
Choosing an NICEIC registered company for your EICR reports in West Bromwich accordingly offers several advantages:
Frequently asked questions
What is an EICR?
An Electrical Installation Condition Report (EICR) is an assessment of the current electrical installation. This test should be carried out by a qualified and skilled person. This checks the current installation is safe and also in compliance with the current BS 7671 standards. Once complete you will be issued a certificate, this will finally give you a satisfactory or unsatisfactory result. Then a report will be issued with details of any observations. Also the report will show any recommendations or immediate actions required.
What happens during an Electrical Installation Condition Report?
Our engineer will conduct a visual inspection of items and both together perform fixed wire testing.
Some of the things we will be looking for during the inspection and test are:
- Both main supply and supplies to distribution boards
- Signs for overheating
- Visual inspection of electrical equipment throughout the electrical system
- Individual circuit testing
- Earth bonding
- Functional testing
Should the installation meet the required standards, we will then issue your electrical installation condition report test certificate. However, if your installation is deemed unsatisfactory, we will provide you with a test certificate. So this along with a detailed report with any faults or improvement works to rectify. This will be complete with images, descriptions of the faults, and observation codes accordingly.
EICR certificate cost West Bromwich? – Pricing guide
Domestic and Landlord EICR Price
Below are estimated guide costs to complete an EICR report for Landlords and Domestic properties. Please note that there are discounts available to landlords. Landlords with multiple properties and also additional services such as PAT testing to add to packages.
- Studio Flat or Apartment – £162.00
- 1 Bedroom Flat or Apartment – £190.00
- 2 Bedroom Flat or Apartment – £216.00
- 2 Bedroom House – £190.00
- 3 Bedroom House – £245.00
all prices are inclusive of VAT.
Commercial EICR Cost
For a small business in a commercial building in West Bromwich. The starting cost of an EICR, generally for one distribution board and ten circuits typically begins at £220, plus VAT.
Industrial EICR Cost
For a small business in an industrial building in West Bromwich. The starting cost of an EICR, generally for one distribution board and ten circuits typically begins at £220, plus VAT.
Also for larger businesses the cost of an EICR in both commercial and industrial premises is made up from a number of factors. For example; the number of distribution boards and also the quantity of circuits. Along with how both complex the premises is and its working environment.
How long does an EICR certificate take to complete?
For both small business premises and houses the time spent carrying out an EICR report in West Bromwich could be a couple of hours.
For larger commercial and industrial properties this depends on the scale of the inspection required. This could range anything from 1-2 days up to a couple of weeks.
For example:
So for an industrial property with 4 large 3 phase distributions boards and 50 circuits in total. We would expect the testing to take approximately 2 – 3 days
EICR Codes
The final outcome of an Electrical Installation Condition Report is either Satisfactory or Unsatisfactory. The following codes are used on the observations sheet in the electrical safety certificate. This is taken from the engineer carrying out the inspection and testing:
C1 – Danger present. There is a Risk of injury. Immediate action required.
C2 – Potentially dangerous – This requires urgent remedial action .
C3 – Improvement recommended.
FI – Further investigation – This is required without delay.
Following any observations with codes C1, C2 and FI will result in an EICR Unsatisfactory final outcome.
How often should I get an EICR test in West Bromwich?
The period between an Electrical Installation Condition Report (EICR) inspection specifically depends on the type of property:
- Domestic property and rental properties: At least every 10 years, or whenever there is a change in occupancy.
- Commercial EICR properties: At least every 5 years.
- Industrial EICR properties: Typically every 3 years.
How do I know when my EICR inspection is due?
So most electrical installations will have a sticker on the distribution board. This will state when the last test was carried out and when the next inspection is due. You can check your last EICR certificate and that will also tell you your dates.
Other Testing Services available in West Bromwich
See below for example some of the other electrical inspection, testing and maintenance services we provide in West Bromwich.
Following or along with an Electrical Installation Condition Report. We can offer the option to bundle various services into both packages and provide discounts where possible. For further details and to discuss these options, please get in touch with us.
See more from our electrical department for related electrical work
Location
Generally we carry out EICR inspections and electrical safety testing in West Bromwich and the West Midlands.